SIMATIC S7-1200 basic controller (PLC)

SIMATIC S7-1200

Compact Siemens controller for small to mid-size machines, with integrated I/O and a PROFINET port; the new S7-1200 G2 generation succeeds the first generation (G1)

Price and delivery time are given after a technical review.

Overview

Overview

SIMATIC S7-1200 is Siemens' compact PLC for basic automation and small to mid-size machines. Every CPU has integrated digital I/O and a PROFINET interface, and is expanded with signal boards (SB), signal modules (SM) and communication modules (CM). High-speed counters, pulse outputs and motion control (positioning axes) are built into the CPU.

Read more

Two generations: G1 and G2

The family now has two generations, and their hardware is not compatible.

  • G1 (first generation): CPU 1211C, 1212C, 1214C, 1215C and 1217C. The CPU 1214C, for example, has 150 KB of work memory, a bit instruction time of 0.08 µs and one PROFINET port.
  • G2 (new generation): CPU 1212C and 1214C and the fail-safe 1212FC and 1214FC, introduced with TIA Portal V20. The CPU 1214C has 1000 KB of work memory (250 KB program and 750 KB data), a bit instruction time of 37 ns, two PROFINET ports with IRT, a Web API and an OPC UA server. It is 80 mm wide, against 110 mm for G1.

In its migration guide Siemens maps the first-generation CPU 1211C, 1212C and 1212FC to the G2 CPU 1212C, and the CPU 1214C, 1215C and 1217C to the G2 CPU 1214C.

Lifecycle

The first generation is on its way out. According to Siemens' migration page the official phase-out announcement dates from 1 November 2026, G1 can be ordered as a new device until October 2027, and spare modules are planned until about 2036. Siemens calls S7-1200 G2 the recommended solution and natural successor, and says future innovations will happen only in G2.

Safety and engineering

The F versions (for example the G2 CPU 1214FC) are rated by the data sheet up to SIL 3 (IEC 61508) and PL e (ISO 13849-1), and PROFIsafe devices connect over PROFINET. Programming is done with STEP 7 in TIA Portal in LAD, FBD and SCL. According to the data sheets the G1 CPU 1214C (firmware V4.7) needs STEP 7 V20 or higher, and the G2 CPU 1214C (firmware V4.1) needs STEP 7 V21 or higher.

Features

  • Compact CPU with integrated digital I/O and a PROFINET interface
  • Two generations: G1 (CPU 1211C to 1217C) and the new G2 (CPU 1212C and 1214C)
  • Expandable with signal boards (SB), signal modules (SM) and communication modules (CM)
  • G2: 1000 KB work memory and a 37 ns bit instruction time in the CPU 1214C
  • G2: two PROFINET ports with IRT, an OPC UA server and a Web API
  • Integrated motion control with up to 8 position-controlled axes
  • Fail-safe F-CPUs (1212FC and 1214FC) and PROFIsafe devices over PROFINET
  • Programmed in TIA Portal with STEP 7 in LAD, FBD and SCL

Advantages

  • G2 uses the same instructions as S7-1500, so know-how and libraries carry over more easily
  • The G2 CPU 1214C takes less room on the DIN rail at 80 mm wide against 110 mm for G1
  • Siemens offers a TIA Add-In to help migrate S7-1200 programs to G2
  • G1 supply continues: new parts can be ordered until October 2027 and spare parts are planned until about 2036

Models and codes

Models and codes
ModelOrder codeCode typeAttributesRequest
CPU 1211C DC/DC/DC (G1)CPU نسل اول با ۶ ورودی و ۴ خروجی دیجیتال و ۲ ورودی آنالوگ؛ ماژول سیگنال نمی‌پذیرد6ES7211-1AE40-0XB0Exact code
Generation:
G1
DI/DO/AI:
6/4/2
Work memory:
75 KB
Firmware:
V4.7
Width:
90 mm
Request CPU 1211C DC/DC/DC (G1)
CPU 1212C DC/DC/DC (G1)CPU نسل اول با ۸ ورودی و ۶ خروجی دیجیتال و ۲ ورودی آنالوگ؛ تا ۲ ماژول سیگنال6ES7212-1AE40-0XB0Exact code
Generation:
G1
DI/DO/AI:
8/6/2
Work memory:
100 KB
Firmware:
V4.7
Width:
90 mm
Request CPU 1212C DC/DC/DC (G1)
CPU 1214C DC/DC/DC (G1)CPU نسل اول با ۱۴ ورودی و ۱۰ خروجی دیجیتال و ۲ ورودی آنالوگ؛ تا ۸ ماژول سیگنال6ES7214-1AG40-0XB0Exact code
Generation:
G1
DI/DO/AI:
14/10/2
Work memory:
150 KB
Firmware:
V4.7
PROFINET ports:
1
Width:
110 mm
Request CPU 1214C DC/DC/DC (G1)
CPU 1215C DC/DC/DC (G1)CPU نسل اول با دو پورت PROFINET، ۱۴ ورودی و ۱۰ خروجی دیجیتال، ۲ ورودی و ۲ خروجی آنالوگ6ES7215-1AG40-0XB0Exact code
Generation:
G1
DI/DO/AI/AO:
14/10/2/2
Work memory:
200 KB
Firmware:
V4.7
PROFINET ports:
2
Width:
130 mm
Request CPU 1215C DC/DC/DC (G1)
CPU 1217C DC/DC/DC (G1)بزرگ‌ترین CPU نسل اول با دو پورت PROFINET و حافظهٔ کاری ۲۵۰ کیلوبایت6ES7217-1AG40-0XB0Exact code
Generation:
G1
DI/DO/AI/AO:
14/10/2/2
Work memory:
250 KB
Firmware:
V4.7
PROFINET ports:
2
Width:
150 mm
Request CPU 1217C DC/DC/DC (G1)
CPU 1212C DC/DC/DC (G2)CPU نسل G2 با ۸ ورودی و ۶ خروجی دیجیتال، دو پورت PROFINET با IRT و حافظهٔ ۱۵۰ کیلوبایت برنامه و ۵۰۰ کیلوبایت داده6ES7212-1AG50-0XB0Exact code
Generation:
G2
DI/DO:
8/6
Work memory:
150 KB program + 500 KB data
Firmware:
V4.1
PROFINET ports:
2
Max. signal modules:
6
Request CPU 1212C DC/DC/DC (G2)
CPU 1214C DC/DC/DC (G2)CPU نسل G2 با ۱۴ ورودی و ۱۰ خروجی دیجیتال، دو پورت PROFINET با IRT و حافظهٔ ۲۵۰ کیلوبایت برنامه و ۷۵۰ کیلوبایت داده6ES7214-1AH50-0XB0Exact code
Generation:
G2
DI/DO:
14/10
Work memory:
250 KB program + 750 KB data
Firmware:
V4.1
PROFINET ports:
2
Max. signal modules:
10
Width:
80 mm
Request CPU 1214C DC/DC/DC (G2)
CPU 1214FC DC/DC/DC (G2)CPU ایمنی (F-CPU) نسل G2 با حافظهٔ ۳۰۰ کیلوبایت برنامه و ۷۵۰ کیلوبایت داده؛ تا SIL 3 و PL e6ES7214-1AF50-0XB0Exact code
Generation:
G2
DI/DO:
14/10
Work memory:
300 KB program + 750 KB data
Firmware:
V4.1
Safety:
SIL 3 / PL e
Width:
80 mm
Request CPU 1214FC DC/DC/DC (G2)
SM 1221 DI 16x24 V DC (G2)ماژول ورودی دیجیتال ۱۶ کاناله ۲۴ ولت برای نسل G2؛ عرض ۳۰ میلی‌متر6ES7221-1BH50-0XB0Exact code
Generation:
G2
Channels:
16 DI
Input voltage:
24 V DC
Width:
30 mm
Request SM 1221 DI 16x24 V DC (G2)
PM 1207 24 V DC / 5 Aمنبع تغذیهٔ تثبیت‌شدهٔ S7-1200 G2 با ورودی ۱۲۰ تا ۲۴۰ ولت AC/DC و خروجی ۲۴ ولت DC / ۵ آمپر6EP3333-4SB00-3AX0Exact code
Input:
120 … 240 V AC/DC
Output:
24 V DC / 5 A
Request PM 1207 24 V DC / 5 A

Technical specifications

Check the specifications against the data sheet of the exact code before ordering.
مشخصات عمومی
GenerationsGenerationsG1: CPU 1211C … 1217C; G2: CPU 1212C, 1214C
CPU supply voltage (DC/DC/DC version)CPU supply voltage (DC/DC/DC version)24 (20.4 … 28.8) V DC
Degree of protectionDegree of protectionIP20
CPU 1214C widthCPU 1214C widthG1: 110; G2: 80 mm
CPU 1214C operating temperature (horizontal)CPU 1214C operating temperature (horizontal)-20 … 60 (G1); -20 … 60 with derating, 40 at full load (G2) °C
حافظه و کارایی
G1 work memoryG1 work memory75 … 250 KB
G2 work memory (program + data)G2 work memory (program + data)CPU 1212C: 150 + 500; CPU 1214C: 250 + 750 KB
Bit instruction time, G1Bit instruction time, G10.08 µs
Bit instruction time, G2Bit instruction time, G237 ns
ورودی/خروجی و توسعه
CPU 1214C integrated I/O (G1)CPU 1214C integrated I/O (G1)14 DI / 10 DO / 2 AI
CPU 1214C integrated I/O (G2)CPU 1214C integrated I/O (G2)14 DI / 10 DO
CPU 1214C expansion capacity (G1)CPU 1214C expansion capacity (G1)8 SM, 1 SB, 3 CM
CPU 1214C expansion capacity (G2)CPU 1214C expansion capacity (G2)10 SM, 2 SB/CB/BB, 3 CM
ارتباطات
G1 PROFINET portsG1 PROFINET ports1 (CPU 1211C … 1214C); 2 (CPU 1215C, 1217C)
G2 PROFINET portsG2 PROFINET ports2, with IRT
Web API and OPC UA server (G2)Web API and OPC UA server (G2)Yes (OPC UA: runtime license required)
کنترل حرکت
Position-controlled axesPosition-controlled axesup to 8 (4 via pulse/direction outputs)
ایمنی
Safety level, CPU 1214FC (G2)Safety level, CPU 1214FC (G2)SIL 3 (IEC 61508), PL e (ISO 13849-1)
G2 cybersecurityG2 cybersecurityIEC 62443-4-2
مهندسی
Programming softwareProgramming softwareG1 (FW V4.7): STEP 7 V20 or higher; G2 (FW V4.1): STEP 7 V21 or higher
چرخهٔ عمر
Siemens plan for G1Siemens plan for G1Announcement 01.11.2026; new devices until October 2027; spare modules until approx. 2036

Modules and accessories

  • Signal Boards SB 1221, SB 1222, SB 1223, SB 1231, SB 1232, SB 1233 (G2)

    Signal boards that add a few digital or analog channels without making the CPU wider; for G2 they include 100 kHz and 200 kHz digital I/O, analog, RTD and thermocouple boards

  • Signal Modules SM 1221, SM 1222, SM 1223, SM 1231, SM 1232, SM 1233 (G2)

    Digital (16-channel) and analog (voltage/current, RTD, thermocouple) I/O modules for G2

  • SM 1226 F-DI 4 / F-DQ 2 / DI 2 (G2)

    Fail-safe I/O module for G2 listed in Siemens' migration guide

  • CM 1241 and CB 1241 communication modules, CSM 1277 G2

    RS232/422/485 serial communication module and board, and the CSM 1277 G2 compact switch module

  • Power supply PM 1207 (24 V DC / 5 A)

    S7-1200 G2 power supply, code 6EP3333-4SB00-3AX0; the Ex version, code 6EP3333-4SC00-3AX0, is listed in Siemens' product overview

  • SIMATIC memory card (4 MB … 32 GB)

    SIMATIC memory card for load memory and firmware updates; G2 CPUs accept up to 32 GB

Documents

Applications

  • Packaging machines
  • Pump and fan control
  • Conveyor systems
  • Temperature control
  • Machine building and special automation projects

Frequently asked questions

Is S7-1200 G2 a direct replacement for the first generation?

No. Siemens states that G2 is not hardware-compatible with the previous S7-1200: the dimensions, terminal positions, Ethernet ports and power connector have changed. Programs can usually be converted with minor adjustments, and Siemens provides a TIA Add-In for this. Before migrating, check the cabinet space and whether the modules you need are available.

Until when can the first-generation S7-1200 be bought new?

According to Siemens' migration page the official phase-out announcement dates from 1 November 2026 and G1 can be ordered as a new device until October 2027; Siemens' own documents differ on the exact day in October, so confirm the date for each order code with Siemens. After that only spare parts are supplied, with spare modules planned until about 2036.

What software is needed to program the S7-1200?

STEP 7 in TIA Portal. According to the data sheets the G1 CPU 1214C with firmware V4.7 needs STEP 7 V20 or higher, and the G2 CPU 1214C with firmware V4.1 needs STEP 7 V21 or higher. The programming languages are LAD, FBD and SCL.

How many expansion modules can a CPU take?

It depends on the CPU. In G1 the CPU 1211C takes no signal module, the CPU 1212C up to 2, and the CPU 1214C, 1215C and 1217C up to 8, all with one signal board and up to 3 communication modules. In G2 the CPU 1212C takes up to 6 and the CPU 1214C up to 10 signal modules, with up to 3 communication modules.

Does the S7-1200 offer safety functions?

Yes. F-CPU versions exist in both G1 and G2. The data sheet of the G2 CPU 1214FC states SIL 3 to IEC 61508 and PL e to ISO 13849-1, and PROFIsafe devices connect over PROFINET. For G2 Siemens also offers the SM 1226 safety module (F-DI 4 / F-DQ 2 / DI 2).

Need SIMATIC S7-1200 basic controller (PLC)?

Send your order code or requirement; after a technical review we give you the price and delivery time.