Skip to main content
Kara TejaratMehr Aein
اینورتر زیمنس SINAMICS G120C، سایز FSAA با پنل اپراتوری IOP-2، نمای سه‌رخ

© Siemens AG

sinamicsSeries G120CActive

SINAMICS G120C frequency converter

SINAMICS G120C

Compact one-piece Siemens frequency converter from 0.55 kW to 132 kW for a three-phase 380 V to 480 V supply; control and power sections in one housing, with an integrated STO safety function

Price and delivery time are given after a technical review.

Overview

Overview

SINAMICS G120C is Siemens' compact converter for control-cabinet mounting (IP20). In the G120 each unit is built from two separate parts, a power module and a control unit; in the G120C these two parts are combined in one housing and the converter is bought under a single article number. The fieldbus version (PROFINET and EtherNet/IP, PROFIBUS DP or USS/Modbus RTU) is also fixed by that article number.

Read more

Siemens positions the G120C for continuous motion with mid-range performance, where more precise control of speed and torque is needed and the converter still has to be small and simple to select.

Range

0.55 kW to 132 kW in seven frame sizes (FSAA to FSF), for a three-phase 380 V to 480 V supply only. All frame sizes can be mounted side by side without derating; frame sizes FSD to FSF have an integrated DC reactor and need no line reactor. Control is V/f (linear, square-law, FCC and ECO) or sensorless vector control, and the braking chopper is integrated.

Safety

The Safe Torque Off (STO) safety function is standard on the converter and needs no external safety component; its level is SIL 2 to EN 61508 and PL d to EN ISO 13849-1. On the PROFINET and PROFIBUS DP versions STO can also be selected over PROFIsafe. In Siemens' Safety Integrated manual only STO is listed for the G120C; functions such as SS1, SBC, SLS, SDI and SSM are not available for it.

G120C or G120

If you need the 200 V or 690 V classes, more than 132 kW, safety functions beyond STO, or the ability to change the fieldbus without changing the power section, the G120 is the better fit. If a smaller converter that is simpler to select is enough, choose the G120C.

Engineering

Commissioning is done with SINAMICS Startdrive inside TIA Portal or with STARTER (the USB port is on the converter itself). The BOP-2 and IOP-2 operator panels and the optional Smart Access module for wireless commissioning from a phone or laptop are available, and parameters are cloned with a panel or a memory card.

Features

  • One-piece build: control and power sections in one unit under one article number
  • 0.55 kW to 132 kW in seven frame sizes, FSAA to FSF
  • Three-phase 380 V to 480 V input
  • STO safety function as standard (SIL 2, PL d), with PROFIsafe on the PROFINET and PROFIBUS DP versions
  • V/f control and sensorless vector control, with the V/f ECO energy-saving mode
  • PROFINET and EtherNet/IP, PROFIBUS DP and USS/Modbus RTU versions
  • Integrated braking chopper, and an integrated DC reactor in FSD to FSF
  • Side-by-side mounting without derating; commissioning with Startdrive, STARTER, BOP-2, IOP-2 or Smart Access

Advantages

  • Takes less cabinet space; Siemens states the FSAA frame size uses up to 30 % less space than comparable converters
  • Simpler to select and order than a G120: one unit instead of two parts
  • STO safety without an external safety relay or its wiring
  • Configured inside the same TIA Portal project as the PLC and the HMI, with parameter cloning for series commissioning

Models and codes

Models and codes
ModelOrder codeCode typeAttributesRequest
G120C USS/MB, 0.55 kW (FSAA)نسخهٔ USS/Modbus RTU، ۰٫۵۵ کیلووات، بدون فیلتر؛ فریم‌سایز FSAA6SL3210-1KE11-8UB2Exact code
Rated power (LO):
0.55 kW
Line filter:
Unfiltered
Communication:
USS, Modbus RTU
Frame size:
FSAA
Dimensions (W × H × D):
73 × 173 × 155 mm
Weight:
1.40 kg
Request G120C USS/MB, 0.55 kW (FSAA)
G120C DP, 0.75 kW (FSAA)نسخهٔ PROFIBUS DP، ۰٫۷۵ کیلووات، بدون فیلتر؛ فریم‌سایز FSAA6SL3210-1KE12-3UP2Exact code
Rated power (LO):
0.75 kW
Line filter:
Unfiltered
Communication:
PROFIBUS DP
Frame size:
FSAA
Dimensions (W × H × D):
73 × 173 × 155 mm
Weight:
1.40 kg
Request G120C DP, 0.75 kW (FSAA)
G120C PN, 1.5 kW (FSAA, filtered)نسخهٔ PROFINET و EtherNet/IP، ۱٫۵ کیلووات، با فیلتر شبکهٔ کلاس A؛ فریم‌سایز FSAA6SL3210-1KE14-3AF2Exact code
Rated power (LO):
1.50 kW
Line filter:
Class A
Communication:
PROFINET, EtherNet/IP
Frame size:
FSAA
Dimensions (W × H × D):
73 × 173 × 160 mm
Weight:
1.40 kg
Request G120C PN, 1.5 kW (FSAA, filtered)
G120C USS/MB, 18.5 kW (FSC, filtered)نسخهٔ USS/Modbus RTU، ۱۸٫۵ کیلووات، با فیلتر شبکهٔ کلاس A؛ فریم‌سایز FSC6SL3210-1KE23-8AB1Exact code
Rated power (LO):
18.50 kW
Line filter:
Class A
Communication:
USS, Modbus RTU
Frame size:
FSC
Dimensions (W × H × D):
140 × 295 × 203 mm
Weight:
4.40 kg
Request G120C USS/MB, 18.5 kW (FSC, filtered)
G120C PN, 22 kW (FSD, filtered)نسخهٔ PROFINET و EtherNet/IP، ۲۲ کیلووات، با فیلتر شبکهٔ کلاس A؛ فریم‌سایز FSD با راکتور DC داخلی6SL3210-1KE24-4AF1Exact code
Rated power (LO):
22.00 kW
Line filter:
Class A
Communication:
PROFINET, EtherNet/IP
Frame size:
FSD
Dimensions (W × H × D):
200 × 472 × 237 mm
Weight:
18.80 kg
Request G120C PN, 22 kW (FSD, filtered)
G120C PN, 55 kW (FSE, filtered)نسخهٔ PROFINET و EtherNet/IP، ۵۵ کیلووات، با فیلتر شبکهٔ کلاس A؛ فریم‌سایز FSE6SL3210-1KE31-1AF1Exact code
Rated power (LO):
55.00 kW
Line filter:
Class A
Communication:
PROFINET, EtherNet/IP
Frame size:
FSE
Dimensions (W × H × D):
275 × 551 × 237 mm
Weight:
28.50 kg
Request G120C PN, 55 kW (FSE, filtered)
G120C PN, 132 kW (FSF, filtered)نسخهٔ PROFINET و EtherNet/IP، ۱۳۲ کیلووات، با فیلتر شبکهٔ کلاس A؛ بزرگ‌ترین فریم‌سایز FSF6SL3210-1KE32-4AF1Exact code
Rated power (LO):
132.00 kW
Line filter:
Class A
Communication:
PROFINET, EtherNet/IP
Frame size:
FSF
Dimensions (W × H × D):
305 × 708 × 357 mm
Weight:
65.50 kg
Request G120C PN, 132 kW (FSF, filtered)

Technical specifications

Check the specifications against the data sheet of the exact code before ordering.
مشخصات عمومی
Power rangePower range0.55 … 132 kW
Voltage familiesVoltage families400 V (3 AC)
Line voltage (400 V class)Line voltage (400 V class)380 … 480 +10 % / -20 % V AC
Frame sizesFrame sizesFSAA, FSA, FSB, FSC, FSD, FSE, FSF
Degree of protectionDegree of protectionIP20 / UL open type
Power section technologyPower section technologyIGBT
Ambient temperature (operation)Ambient temperature (operation)-10 … 40 (FSAA-FSC) or -20 … 40 (FSD-FSF) without derating; up to 50 with derating °C
Output frequencyOutput frequency0 … 550 (V/f), 0 … 240 (vector) Hz
Overload capabilityOverload capabilityLO: 150 % for 3 s then 110 % for 57 s; HO: 200 % for 3 s then 150 % for 57 s (300 s cycle)
Energy efficiency classEnergy efficiency classIE2 (IEC 61800-9-2)
کنترل
Control modesControl modesV/f (linear, square-law, FCC, ECO), sensorless vector control (SLVC)
BrakingBrakingIntegrated braking chopper; external braking resistor
ورودی و خروجی
Integrated inputs and outputsIntegrated inputs and outputs6 DI, 1 AI, 1 AO, 2 DO (1 relay, 1 transistor)
ایمنی
Safety integrity levelSafety integrity levelSIL 2 (EN 61508), PL d (EN ISO 13849-1)
Safety functionsSafety functionsSTO
ارتباطات
Fieldbus protocolsFieldbus protocolsPROFINET, EtherNet/IP, PROFIBUS DP, USS, Modbus RTU
Fieldbus by frame sizeFieldbus by frame sizeFSAA-FSC: PROFINET, EtherNet/IP, PROFIBUS DP, USS/Modbus RTU; FSD-FSF: PROFINET, EtherNet/IP
مهندسی
Commissioning softwareCommissioning softwareSINAMICS Startdrive (TIA Portal), STARTER
Operator panels and toolsOperator panels and toolsBOP-2, IOP-2, IOP Handheld, Smart Access, USB port, memory card
FirmwareFirmware4.7 SP14 (operating instructions 02/2026)

Modules and accessories

  • Basic Operator Panel BOP-2

    Two-line operator panel for local commissioning, troubleshooting and control of the drive; supports parameter cloning

  • Intelligent Operator Panel IOP-2

    Graphical operator panel with commissioning wizards for local commissioning, diagnostics and monitoring

  • SINAMICS G120 Smart Access

    Optional web server module for wireless commissioning, operation and diagnostics from a phone, tablet or laptop

  • SINAMICS SD memory card

    Memory card that stores the converter's parameters; after a converter is replaced the settings are loaded back from the card

  • Braking resistor

    External braking resistor that dissipates excess DC-link energy; works with the G120C's integrated braking chopper

  • Line reactor

    Line reactor that smooths the current drawn from the supply and reduces harmonics; not needed on FSD to FSF because they have an integrated DC reactor

  • Class B line filter

    External Class B line filter for a higher radio-interference class

  • Output reactor

    Output reactor that reduces the voltage rise rate (dv/dt) and current peaks and allows longer motor cables

Documents

Applications

  • Conveyors: belt, roller, chain and bucket
  • Pumps, fans and compressors
  • Mixers, agitators, centrifuges, mills and crushers
  • Extruders and rotary furnaces
  • Basic handling machines

Frequently asked questions

How does the G120C differ from the G120, and which should I choose?

The G120 is modular: the power module and control unit are ordered separately, it covers the 200 V, 400 V and 690 V classes and powers up to 250 kW, and with F control units it has extended safety functions. The G120C is one piece: 0.55 kW to 132 kW, three-phase 380 V to 480 V only, and STO as its only safety function. If a smaller converter, simpler selection and STO are enough, take the G120C; if you need a higher voltage or power, wider safety functions, or a fieldbus change without changing the power section, take the G120.

How is the fieldbus version (PROFINET, PROFIBUS, USS) chosen?

On the G120C the fieldbus version is part of the article number. In Siemens-generated data sheets, …UB2 carries USS/Modbus RTU, …UP2 PROFIBUS DP, and …UF2 or …AF2 PROFINET and EtherNet/IP. According to the Siemens brochure, frame sizes FSAA to FSC come in all four versions and FSD to FSF only with PROFINET and EtherNet/IP; confirm the exact code in the Industry Mall before ordering.

Does the G120C have a safety function?

Yes, STO as standard, at SIL 2 to EN 61508 and PL d to EN ISO 13849-1. The fail-safe input is on DI 4 and DI 5, and on the PROFINET and PROFIBUS DP versions STO can also be selected over PROFIsafe. Other functions such as SS1 or SLS are not available for the G120C.

What software and tools commission the G120C?

With SINAMICS Startdrive inside TIA Portal or with STARTER, through the USB port on the converter. The BOP-2 or IOP-2 serve local commissioning and the Smart Access module serves wireless commissioning. Parameters are cloned with the BOP-2, the IOP-2 or a memory card.

Is an external braking resistor needed for braking?

The braking chopper is inside the G120C, but the excess DC-link energy has to be dissipated in an external braking resistor. These resistors are designed for the G120C, and for an EMC-compliant connection on frame sizes FSD to FSF the matching shield connection kit must be ordered as well.

Need SINAMICS G120C frequency converter?

Send your order code or requirement; after a technical review we give you the price and delivery time.